Permits for simple projects, which do not require plan check, are readily issued as Express Permits or e-permits when done online.
All contractors must complete a subcontractor form providing information on any subcontractors used on the project. This form must be returned to the Office of Finance
Filtered categories:
Door maneuvering clearances are determined based on Approach Direction -- from the front, hinge side, latch side, approach side, pull or push side -- whether the path is perpendicular or parallel to a doorway.
See Table 11B-404.2.4.1 for each case scenario.
Was this helpful?
¼ inch is the maximum.
Was this helpful?
34 inches is the maximum height.
Was this helpful?
36 inches is the maximum height.
Was this helpful?
The slope requirements for different parts of an accessible route vary.
Walkways 5%
Ramps 8.33%
Landings 2%
Elevator car 2%
Accessible parking 2%
Was this helpful?
8.33% is the maximum for a ramp slope.
Was this helpful?
36” minimum, if serving elements are on only one side; otherwise 44” minimum.
Was this helpful?
The clear width of walking surfaces must be 36 inches minimum
Was this helpful?
30” x 48” is the minimum width.
Was this helpful?