The ETL evaluates electrical equipment for safety, fire and shock hazards and personnel injuries in accordance with the current applicable codes and standards. Approved materials are published as Los Angeles Research Reports (LARR).
Electrical Testing Laboratory
Address: 221 N. Figueroa St. Room 500, Los Angeles, CA 90012
Telephone: (213) 482-6721 Fax: (213) 482-6554
Engineer: Antonio Maldonado
Email: antonio.maldonado@lacity.org Telephone: (213) 482-7382
Engineer: Isaac Almaraz
Email: isaac.almaraz@lacity.org Telephone: (213) 482-0035
Engineer: Stephanie Lopez
Email: stephanie.j.lopez@lacity.org Telephone: (213) 482-0068
Find Building Permit-related PDFs and forms here. For more options, visit our Forms and Publications page.
Filtered categories:
Door maneuvering clearances are determined based on Approach Direction -- from the front, hinge side, latch side, approach side, pull or push side -- whether the path is perpendicular or parallel to a doorway.
See Table 11B-404.2.4.1 for each case scenario.
Was this helpful?
¼ inch is the maximum.
Was this helpful?
34 inches is the maximum height.
Was this helpful?
36 inches is the maximum height.
Was this helpful?
The slope requirements for different parts of an accessible route vary.
Walkways 5%
Ramps 8.33%
Landings 2%
Elevator car 2%
Accessible parking 2%
Was this helpful?
8.33% is the maximum for a ramp slope.
Was this helpful?
36” minimum, if serving elements are on only one side; otherwise 44” minimum.
Was this helpful?
The clear width of walking surfaces must be 36 inches minimum
Was this helpful?
30” x 48” is the minimum width.
Was this helpful?